This is an old revision of the document!
$/hour
to the page
our current sensor is clamped onto our three main arteries
and is streamed using rtl_433
running on the HomeAssistant “cloud” machine
push it to over mqtt, using
sudo rtl_433 -F "mqtt://10.81.2.3:1883,user=tami,pass=tamispace"
and from there to the homeassistant
in hass, as our sensor does not conform to the standard power_w
expected output.
a solution was found, and integrated to hass configuration.yaml
tl;dr
add the following to the config/configuration.yaml
and reload the yaml (Developer Tools/yaml
)
mqtt: sensor: - name: cc_power0 state_topic: rtl_433/74930c0d-rtl433/devices/CurrentCost-TX/3202/power0_W device_class: power unit_of_measurement: W state_class: measurement value_template: "{{ value | round() }}" - name: cc_power1 state_topic: rtl_433/74930c0d-rtl433/devices/CurrentCost-TX/3202/power1_W device_class: power unit_of_measurement: W state_class: measurement value_template: "{{ value | round() }}" - name: cc_power2 state_topic: rtl_433/74930c0d-rtl433/devices/CurrentCost-TX/3202/power2_W device_class: power unit_of_measurement: W state_class: measurement value_template: "{{ value | round() }}"